Connect a PLC project
Create an empty PLC project in TwinCAT and select its .plcproj in ETAB. The companion model is created or reopened alongside it.
Describe components, areas and relationships in the visual editor. ETAB turns them into a TwinCAT PLC template based on ET_AutomationBase.
Machine structure and contracts are modelled explicitly. The actual process logic remains project-specific.
Create an empty PLC project in TwinCAT and select its .plcproj in ETAB. The companion model is created or reopened alongside it.
Place components by drag and drop. Organise them into areas and define hierarchy, commands, request and status fields, and relationships.
Components + contractsSave the model and open the generation preview. Review files, conflicts and the planned project changes, including task changes where applicable.
Generation previewConfirm the target and write operation. ETAB creates the managed artifacts and integrates them into the linked TwinCAT project.
TwinCAT PLC artifactsFour directly modelled node types from the EngineeringToolbox AutomationBase library.
Machine, motion, workpiece or process unit. A unit connects the ET state model to commands and project-specific data contracts.
Generates: command enum, request/status DUTs, base FB
Command execution and sequence coordination without a separate ET state model. You write the actual CASE or sequence logic in the project.
Generates: command and contract scaffold
Describe the recipe data type, file, path and options. Domain data structures and validation logic remain project-specific.
Generates: instance, configuration, status contract
Model a logical machine connection with role, bridge type, watchdog and token options. Hardware addressing is configured in the project.
Generates: instance, Rx/Tx and status contract
The editor and CLI use the same core. Every generation starts with a concrete plan you can review.
// Simplified PLC project output PLC/ ├── PLC.plcproj ├── PLC.etab.json ├── Application/ │ └── Area/ │ └── Unit/ │ ├── E_…Command.TcDUT │ ├── ST_…Request.TcDUT │ ├── ST_…Status.TcDUT │ └── FB_…Base.TcPOU └── ETAB/ ├── Shared/ └── Runtime/ // optional
Output depends on the model, node type and enabled options.
Invalid or unsaved models, conflicts and stale previews prevent generation. Duplicate IEC object names are checked in advance.
ETAB manages the files and entries recorded in its manifest. Optional ApplicationUnit user stubs are created once and are not overwritten afterwards.
When runtime generation is enabled, the preview also shows the planned task change. Ambiguous task assignments are blocked.
The model describes structure and contracts. Process sequences, hardware binding and machine behaviour still need their own implementation and verification.
For the OmniGrind model, the README documents 36 nodes, 62 relationships and 168 managed artifacts, along with a successful TwinCAT "Rebuild All". Online runtime, simulation, safety and machine acceptance are separate checks that remain necessary. Status and evidence ↗
The Windows x64 version includes the application and local service. The target computer needs neither the .NET SDK nor Node.js.
Run the installer. A normal installation is per-user without elevation. If WebView2 is missing, Setup installs the runtime through Microsoft.
Use ET_AutomationBase 0.1.0.4 and the original EngineeringToolbox dependency. The library is provided separately.
Create an empty PLC project in TwinCAT. Open ETAB and choose "Connect TwinCAT PLC Project". Then model your first machine structure.
Windows x64 · Installer or portable version
Extract the entire portable ZIP and run ETAB Engineering.exe. WebView2 must already be installed for the portable version. Setup needs an internet connection to install the runtime if it is missing.
Latest release, notes and checksums ↗ · Windows package details ↗
From your first project to the data model and generation contract. These references link directly to the versioned repository documentation.
Connect a project, edit components and review a generation plan.
02Node types, library foundations and modelling boundaries.
03Project structure, stable IDs, data contracts and relationships.
04Naming, managed files and regeneration rules.
05A reference model for understanding the generator output.
06validate, preview, generate and check, using the same core as the editor.
The released application is a Windows desktop program with WebView2 and a local service. This website explains the tool and links to downloads. It does not access your PLC project.
ETAB generates a structured PLC template from your model. Domain sequences, project-specific logic, hardware addressing and machine acceptance remain engineering tasks.
Project integration distinguishes managed artifacts from existing project files. Compatible existing entries are not taken over, and conflicts block writes. Still review the concrete preview before each generation and keep your projects under version control.
You need a TwinCAT PLC project and the EngineeringToolbox and ET_AutomationBase libraries. This does not claim approval for every TwinCAT version or machine configuration. See the repository validation records for the tested scope.